Megger FT4 up to 4kV

Megger FT4 up to 4kV


Home

 

Megger FT4 up to 4kV

  • Ideal for testing Class 1 and Class 2 equipment
  • Two ranges of test voltage
  • Output control has safety zero interlock
  • 'Breakdown', 'Trip Level' and 'Burn' modes of operation
  • Audible and visual indication of breakdown and excessive leakage current

The MEGGER FT4 Flash Tester operates from the mains supply and provides a continuously variable a.c. test voltage up to a maximum of 4 kV. The a.c. voltage frequency is that of the supply. A simple function switch permits selection of one of the three modes of operation ‘Breakdown’, ‘Trip Level’ and ‘Burn’.

In the ‘Breakdown’ mode the instrument responds only to the high frequency signals produced by the flashing arc of breakdown and trips the test voltage only when this occurs. In the ‘Trip Level’ mode the output voltage is tripped when the pre-set threshold level of leakage current is exceeded or if breakdown occurs. For the ‘Burn’ mode of operation the output is maintained irrespective of leakage current or breakdown; the output voltage drops to limit the level of current flowing.

Leakage and breakdown failure are indicated by the illumination of the fail lamp and the sounding of an internal buzzer. In the ‘Trip Level’ mode, the pre-set leakage current level is variable between 0,3 mA and 3 mA. Leakage current in all modes is indicated on an analogue meter.

In the ‘Burn’ mode, neither the failure signals nor the circuit tripping occurs, but the voltage drops to limit the current flowing during burning at the fault. The ‘Burn’ mode is provided to enable the point of breakdown failure to be located. As a safety feature, when the output voltage is tripped due to a failure in the test item, an interlock system keeps the voltage switched off until the circuit is manually re-set by turning the voltage control to zero. The equipment is designed to BS and IEC safety standards.

Output sockets are provided for the two ranges and there is a common earth terminal. An illuminated power supply switch indicates when the instrument is connected to an energized supply and another lamp illuminates to warn that the output test voltage is being applied. The instrument is robust and built into a strong, portable, plastic case, with a cover

 

Top Of Page  
BACK TO:  Flash Testers
To add this site to your favourites click here

Search this site  

 

Test & Measurement Hire ltd, 16 Swordfish Close, Swordfish Business Park, Burscough, Lancs, L40 8JW
 Phone is 0870 787 0105, Fax is 0870 787 0106
Contact : Hire Manager : Ken Carine


Measurement House, Units 12/13 Harlaw Industrial Estate, Harlaw Way, Inverurie, Aberdeenshire, AB51 4SG
Phone is 0870 787 0103, Fax is 0870 787 0104
Contact : Area Manager : Gordon Thow

 
Visit our Environmental Monitoring Services website