Test Equipment & Instrumentation, Hire, Sales & Technical Services


Testo 350XL Diesel Engine Combustion Analyser

Testo 350XL Diesel Engine Combustion Analyser


Home

 

Testo 350XL Diesel Engine Combustion Analyser

The Testo 350 flue gas analyser is a flexible, portable measuring system which fulfills a wide range of requirements.

For this reason, the analyser can be used to:

  • Adjust all types of industrial burners

  • Measure concentrations in crude and clean gas over a longer period of time

  • Check the atmosphere of all types of process furnace

  • Maintain stationary motors such as block-type thermal power stations

  • Check gas pressures and gas velocities in flue gas and also in additional air ducts


The 350XL consists of a control unit, analysis box and a flue gas probe. O2, CO, NO (option) NO2, SO2, CxHy and H2S (options), temperature and differential pressure as well as the usual calculated values CO2 etc.

The detachable control unit can also be used as a separate analyser for temperature, velocity, differential pressure, relative humidity etc. The readings can be printed on the integrated printer.

A complete Pelter gas preparation unit for controlled condensate disposal is built into the analysis box.

Advantages of 350XL at a glance

  • Battery operation, also with gas preparation unit

  • Analysis box with data logging function allows measurement without control unit.

  • Radio control (option) between control unit and analysis box.

  • Easy and fast operation via touch panel display.

  • Measuring range extension (option) for CO

  • Suitable flue gas probe for every application.

  • Extremely high accuracies in the lower ranges for CO and NO.

  • Easy handling thanks to low weight and compact size.

  • Can withstand tough conditions thanks to sturdy transport case.

 Specifications - Testo 350
O2 CO CO low NO NO low NO² SO2 H2S CxHy
Range 0-25% Vol 0-10,000ppm H² Comp. 0-500ppm 0-3000ppm 0-300ppm 0-500ppm 0-5000ppm 0-300ppm 0-4%
Accy. <0.8% of f.v <5ppm 0-99ppm <5%m.v. 100-2000ppm <10%m.v. 2,001 - 10,000 ppm <2ppm 0-39.9ppm <5%m.v. 40-500ppm <5ppm 0-99ppm <5%m.v. 100-2000ppm <10%m.v. 2,001 - 10,000 ppm <2ppm 0.39.9ppm <5%m.v. 300ppm <5ppm 0-99ppm <5% of m.v 500ppm <5ppm 0-99ppm <5%m.v. 100-2000ppm <10%m.v. 2,001 - 5,000 ppm <2ppm 0-39.9ppm <5%m.v. 40-300ppm <0.004% Vol. 0-0.4% Vol. <10% of m.v. 0.41-4%Vol.
Res.tion 0.1% Vol 1ppm 0.1ppm 1ppm 0.1ppm 0.1ppm 1ppm 0.1ppm 0.01 Vol. %
Resp. Time 20s (t95) 40s (t90) 40s (t90) 30s (t90) 30s (t90) 40s (t90) 30s (t90) 35s (t90) 40s (t90)

  CO2 Differential Pressure 1 Differential Pressure 2 Efficiency Flow Velocity Current Voltage Current Voltage RPM Temp.
Range 0-CO2 Max. -200 to + 200hPa -40 to + 40 hPa 0-100% 0-40m/s 0-20mA 0-10V 20-20,000rpm -40 to +1200°C
Accy Calculated from O2 ±1% of m.v. (-50 to -200hPa) ±1% of m.v. (+50 to +200hPa)±0.5hPa (-49.9 to +49.9hPa) ±1% of m.v. (-40 to +3hPa) ±1% of m.v. (+3 to +40hPa) ±0.03hPa (-2.99 to +2.99hPa)     ±0.04 mA ±0.01 mA   ±0.5% of m.v (+100 to +1200°C

±0.5°C )-40 to +99.9°C)

Resolution 0.1% Vol 0.1 hPa 0.01 hPa 0.1% 0.1m/s ±0.01 mA ±0.01 mA 1rpm  

 

Dimensions 395 x275 x 95mm Analyser Box Bat NiMH 2-3hr Warranty Info  
Weight 4.5kg Control Unit Bat. 4 AA, 8hrs Analyser 2 years
Storage Temperature -20 to + 50°C Max. Pos. Pressure 50mbar O2 Cell 1.5 years
Operating Temperature -5 to + 45°C Max. Neg Pressure 200mbar CO, NO, NO2,SO2 1 year
Material ABS CO Dilution Factors 0,2,5,10,20,40 Accuracy Readings + 2% Gas Fresh Air or N² Probe, battery, printer 1 year
Memory 250,000 readings      
Power required 90-260V or rechargeable battery      

 

Top Of Page
BACK TO:  Combustion Gas Analysers
To add this site to your favourites click here

Search this site  

 

Test & Measurement Hire ltd, 16 Swordfish Close, Swordfish Business Park, Burscough, Lancs, L40 8JW
 Phone is 0870 787 0105, Fax is 0870 787 0106
Contact : Hire Manager : Ken Carine


Measurement House, Units 12/13 Harlaw Industrial Estate, Harlaw Way, Inverurie, Aberdeenshire, AB51 4SG
Phone is 0870 787 0103, Fax is 0870 787 0104
Contact : Area Manager : Gordon Thow

 
Visit our Environmental Monitoring Services website